E271-2201 AccuTouch SmartSet Bus Controller
Controller Configurations • BUSSTAT

| Base I/O Address |
J0 |
J1 |
| 280h * |
Out |
Out |
| 180h |
Out |
In |
| 240h |
In |
Out |
| 100h |
In |
In |
| 2A0h |
Connect left pins of J0 and J1 |
* Factory default
| IRQ |
J2 |
J3 |
| Software selectable * |
Out |
Out |
| 3 |
Out |
In |
| 5 |
In |
Out |
| 2 |
In |
In |
| 7 |
Connect left pins of J2 and J3 |
* Factory default
| Emulation |
J10 |
J11 |
| None * |
Out |
N/A |
| None |
Out |
N/A |
| E271-141, 12 bit |
In |
Out |
| E271-141, 8 bit |
In |
In |
* Factory default
| Jumper |
In |
Out |
| 7 |
Power on settings from Jumpers * |
Power on settings from NVRAM |
| 6 |
N/A |
Reserved * |
| 5 |
AccuTouch * |
Duratouch |
| 4 |
Point |
Stream * |
* Factory default
Power Requirements
- +5VDC ± 10%, 250 mA typical
- +125VDC ± 10%, 75 mA typical
|